GMP & ISO 14644 Certified
PT. Far Clean Indonesia Cleanroom
Pilih Bahasa / Language:
Pass Box — Pass Box Statis & Dinamis untuk Transfer Material Cleanroom – PT Far Clean Indonesia
Pass Box Statis & Dinamis
Jaminan Kualitas & Kepatuhan cGMP

Struktur baja tahan karat SUS304 presisi dengan sistem interlock mekanis/elektrik dan lampu UV germisidal untuk transfer material bebas kontaminasi.

Peralatan Steril Cleanroom ID: fc-passbox-uv

Pass Box Stainless Steel: Sterilisasi UV & Ukuran Kustom

Jendela Transfer Material Kelas Atas untuk Cleanroom Farmasi & Lab

Jelajahi pass box statis dan dinamis yang dirancang untuk transfer material cleanroom yang aman dan bebas kontaminasi. Pelajari tentang filtrasi HEPA, sistem interlock, fitur, aplikasi, dan cara memilih pass box cleanroom yang tepat untuk fasilitas Anda.

Rekomendasi Aplikasi Industri:

Fasilitas Farmasi & API Laboratorium Keselamatan Hayati & Mikrobiologi Semikonduktor & Mikroelektronika Suite Pengemasan Alat Kesehatan Makanan, Kosmetik & Nutrasetikal

Keunggulan & Fitur Utama:

  • ✓ Sistem Interlock Pintu: Pintu ganda dengan interlock mekanis atau elektromagnetik mencegah kedua sisi terbuka bersamaan.
  • ✓ SUS304 / SUS316L bermutu tinggi: Dinding dalam baja nirkarat bebas korosi dengan sudut melengkung coved radius mudah dibersihkan.
  • ✓ UV - Pembunuh Kuman Terintegrasi: Dilengkapi lampu sterilisasi UV 253.7nm dengan sakelar keselamatan otomatis saat pintu dibuka.
  • ✓ Jendela Kaca Temper Rata (Flush): Jendela pandang ganda rata (flush) memudahkan inspeksi visual barang tanpa membuka pintu.

* Kustomisasi dimensi ruang (chamber), opsi interlock mekanis atau elektrik, material SUS304 / SUS316L, dan integrasi dinding panel modular.

Sistem Transfer Material Higienis Cleanroom

Pass Box — Pass Box Statis & Dinamis untuk Transfer Material Cleanroom

Kotak pass adalah perangkat transfer penting yang digunakan untuk memindahkan material antar cleanroom atau antara lingkungan terkendali dan tidak terkendali. Unit ini membantu menjaga tingkat kebersihan, meminimalkan kontaminasi partikel, dan menghindari pergerakan personel yang tidak perlu. Dengan pemilihan dan pemasangan yang tepat, pass box dapat meningkatkan efisiensi alur kerja secara signifikan dan mengurangi beban penanganan udara di fasilitas manufaktur farmasi, semikonduktor, bioteknologi, dan optik.

Pass Box — Pass Box Statis & Dinamis untuk Transfer Material Cleanroom – PT Far Clean Indonesia

Farclean memproduksi Pass Box Statis dan Dynamic Pass Box dengan struktur baja tahan karat, penyegelan kedap udara, opsi filtrasi HEPA, dan sistem interlock canggih yang memenuhi persyaratan ISO 14644 dan GMP.

Apa Itu Pass Box Cleanroom?

Pass box cleanroom adalah ruang khusus yang dipasang di dalam dinding cleanroom untuk memindahkan material antar klasifikasi kebersihan yang berbeda. Tujuan utamanya adalah untuk mencegah kontaminasi, menjaga tekanan diferensial dan mengurangi kehilangan udara antar ruangan. Pass box tersedia dalam berbagai konfigurasi berdasarkan tingkat kebersihan, frekuensi transfer, dan standar kebersihan yang diperlukan oleh proses produksi.

Penggunaan umum meliputi:

  • • Memindahkan bahan mentah, peralatan dan produk setengah jadi
  • • Memindahkan sampel, bahan kimia, atau peralatan kecil
  • • Pengiriman bahan pengemas atau wadah
  • • Mencegah kontaminasi silang antar zona cleanroom

Pass Box Statis

Pass Box Statis dipasang di antara ruangan dengan tingkat kebersihan yang sama. Unit ini tidak memiliki kipas (fan) atau sistem penyaringan HEPA dan hanya mengandalkan pintu yang saling interlock untuk menjaga isolasi. Pass box statis banyak digunakan di laboratorium, ruang pengemasan, area pemrosesan makanan, dan lingkungan bersih berisiko rendah.

Fitur Utama

  • Ruang internal baja tahan karat SUS304/SUS316 yang tahan lama
  • Sistem interlock mekanis atau elektromagnetik
  • Jendela kaca temper untuk memudahkan pengamatan
  • Sudut membulat halus untuk memudahkan pembersihan
  • Lampu UV opsional untuk sterilisasi

Keuntungan Utama

  • Biaya investasi lebih rendah
  • Struktur sederhana, perawatan mudah
  • Tanpa konsumsi daya terus-menerus
  • Keandalan operasional yang tinggi dan masa pakai yang lama

Dynamic Pass Box

Dynamic Pass Box dilengkapi dengan sistem filtrasi HEPA/ULPA internal dan beroperasi dengan aliran udara bertekanan positif. Unit ini digunakan saat memindahkan material dari area dengan kualitas lebih rendah ke cleanroom dengan kualitas lebih tinggi. Unit ini berfungsi seperti ruang pembersih udara mini, menghilangkan debu dan partikel sebelum membuka ke zona pembersih.

Fitur Utama

  • Filter HEPA H13/H14 atau ULPA efisiensi tinggi
  • Motor kipas EC menyediakan aliran udara laminar yang stabil
  • Tampilan digital untuk tekanan dan status pengoperasian
  • Interlock elektromagnetik untuk keamanan pintu
  • Sistem kontrol layar sentuh PLC opsional

Keuntungan Utama

  • Memastikan kebersihan material saat dipindahkan
  • Meningkatkan kepatuhan GMP untuk transisi antar-grade yang kritis
  • Mempertahankan tekanan dan mencegah kontaminasi aliran balik
  • Pembersihan partikel aktif dalam 15–30 detik

Pass Box Statis vs. Dinamis — Perbandingan Terperinci

Kategori Pass Box Statis Dynamic Pass Box
Aliran udara Tanpa kipas atau filter (Isolasi pasif) Aliran udara laminar yang disaring HEPA/ULPA
Kontrol Kebersihan Pengendalian kontaminasi dasar Reduksi partikel aktif tingkat tinggi
Aplikasi Terbaik Lingkungan ISO 7–8, ruangan kelas setara ISO 5–7, zona batas GMP Kelas B/C/A
Instalasi Persyaratan konstruksi minimal Membutuhkan catu daya & desain aliran udara
Biaya Investasi lebih hemat Investasi lebih tinggi untuk kepatuhan kritis

Cara Memilih Pass Box yang Tepat untuk Fasilitas Anda

Memilih pass box yang tepat bergantung pada beberapa faktor:

  • 1 Perbedaan tingkat kebersihan: Gunakan pass box statis untuk kelas kebersihan yang sama (misalnya Kelas D ke D); gunakan dynamic pass box ketika melakukan transisi ke zona bersih yang lebih tinggi (misalnya Kelas C ke B).
  • 2 Jenis bahan & transfer frekuensi: Ukur ruangan dengan benar untuk memastikan material tidak menghalangi penutupan pintu atau nozel aliran udara.
  • 3 Persyaratan peraturan: Memastikan kepatuhan terhadap protokol validasi cGMP, ISO 14644-4, dan FDA.
  • 4 Preferensi interlock: Pilih interlock mekanis untuk keandalan tanpa daya atau interlock elektromagnetik untuk indikator audio/visual dan sterilisasi berwaktu.

Pertanyaan yang Sering Diajukan (FAQ)

Kapan sebaiknya memilih Static Pass Box dibandingkan Dynamic Pass Box?

Static Pass Box adalah pilihan paling tepat dan hemat biaya jika transfer barang dilakukan antara dua ruangan dengan kelas kebersihan yang sama (misalnya dari Koridor Kelas D ke Ruang Kemas Primer Kelas D, atau antar ruang laboratorium non-steril). Sistem interlock mekanis/elektrik sudah cukup untuk mengisolasi kedua ruangan tanpa perlu filter hembusan udara.

Apa perbedaan interlock mekanis dan interlock elektronik?

Interlock mekanis bekerja murni dengan tuas/kawat baja internal tanpa memerlukan daya listrik, sangat awet dan tahan lama. Interlock elektronik menggunakan sensor magnetik dan solenoid listrik, memungkinkan integrasi lampu indikator (hijau/merah), tombol darurat, buzzer, dan timer otomatis untuk lampu UV.

Berapa ukuran dimensi standar dan apakah bisa dipesan custom?

Ukuran dimensi internal standar yang paling umum adalah 500x500x500 mm, 600x600x600 mm, dan 800x800x800 mm. Farclean memproduksi unit secara *kustom* untuk menyesuaikan ukuran baki, troli transfer, atau ketebalan panel dinding cleanroom proyek Anda.

Tabel Spesifikasi Teknis Lengkap

Material Ruang (Chamber) Full Stainless Steel SUS304 / SUS316L Hairline (ketebalan 1,2–1,5 mm)
Mekanisme Interlock Interlock Mekanis / Interlock Elektromagnetik Presisi dengan Indikator Status LED
Jendela Observasi Kaca Temper Flush Dua Lapis (5 mm + 5 mm dengan Silica Gel Desiccant)
Disinfeksi UV Germisidal Lampu UV-C Germisidal 253,7 nm dengan Timer Interlock Otomatis dan Interlock Pengaman Pintu
Desain Sudut Sudut Interior Melengkung Penuh (R ≥ 10 mm, Tanpa Perangkap Debu)
Segel Gasket Gasket Hermetik Silikon Sel Tertutup / EPDM Berkelanjutan
Dimensi Standar Internal 500 x 500 x 500 mm / 600 x 600 x 600 mm / 800 x 800 x 800 mm (Tersedia Kustom)
Sertifikasi Kepatuhan ISO 14644-1 (Kelas 1–9), cGMP Grade A–D, FDA 21 CFR, Bersertifikat CE

Butuh Spesifikasi Khusus atau Proyek Terpadu?

Konsultasikan kebutuhan pass box statis/dinamis SUS304/SUS316L, interlock elektronik, sterilisasi UV, atau fasilitas cleanroom cGMP Anda dengan tim ahli kami di Indonesia.

Pass Boxes — Static & Dynamic Pass Box for Cleanroom Material Transfer – PT Far Clean Indonesia
Static & Dynamic Pass Box
Quality Assurance & cGMP Compliance

Precision SUS304 stainless steel structure with mechanical/electrical interlock system and germicidal UV lamp for contamination-free material transfer.

Sterile Cleanroom Equipment ID: fc-passbox-static
Stainless Steel Pass Box: UV Sterilization & Custom Sizes

High-Grade Material Transfer Windows for Cleanrooms

Explore static and dynamic pass boxes designed for safe, contamination-free cleanroom material transfer. Learn about HEPA filtration, interlocking systems, features, applications and how to choose the right cleanroom pass box for your facility.

Industrial Application Recommendations:

Pharmaceutical & API Facilities Biological Safety & Microbiology Labs Semiconductors & Microelectronics Medical Device Packaging Suites Food, Cosmetics & Nutraceuticals

Key Advantages & Features:

  • ✓ Interlocking Door System: Double doors with mechanical or electromagnetic interlocks prevent both sides from opening at the same time.
  • ✓ High-Grade SUS304 / SUS316L: Corrosion-free stainless steel inner walls with coved radius curved corners are easy to clean.
  • ✓ Integrated Germicidal UV-C: Equipped with a 253.7nm UV sterilization lamp with automatic safety switch when the door is opened.
  • ✓ Flush Tempered Glass Window: Flush double viewing window allows for easy visual inspection of items without opening the door.

* Customization of chamber dimensions, mechanical or electrical interlock options, SUS304 / SUS316L material, and modular panel wall integration.

Cleanroom Hygienic Material Transfer System

Pass Boxes — Static & Dynamic Pass Box for Cleanroom Material Transfer

Pass boxes are essential transfer devices used to move materials between cleanrooms or between controlled and non-controlled environments. They help maintain cleanliness levels, minimize particle contamination and avoid unnecessary personnel movement. With proper selection and installation, pass boxes can significantly improve workflow efficiency and reduce air handling loads in pharmaceutical, semiconductor, biotech and optical manufacturing facilities.

Pass Boxes — Static & Dynamic Pass Box for Cleanroom Material Transfer – PT Far Clean Indonesia

Farclean manufactures both Static Pass Boxes and Dynamic Pass Boxes with stainless steel structures, airtight sealing, HEPA filtration options and advanced interlock systems that meet ISO 14644 and GMP requirements.

What Is a Cleanroom Pass Box?

A cleanroom pass box is a specialized chamber mounted within a cleanroom wall to transfer materials between different cleanliness classifications. The main purpose is to prevent contamination, maintain differential pressure and reduce air loss between rooms. Pass boxes are available in multiple configurations based on cleanliness grade, transfer frequency and hygiene standards required by the production process.

Typical uses include:

  • • Transferring raw materials, tools and semi-finished products
  • • Moving samples, chemicals or small equipment
  • • Delivering packaging materials or containers
  • • Preventing cross-contamination between cleanroom zones

Static Pass Box

Static Pass Boxes are installed between rooms with similar or equal cleanliness levels. They do not contain fans or HEPA filtration systems and rely solely on interlocked doors to maintain isolation. Static pass boxes are widely used in laboratories, packaging rooms, food processing areas and low-risk clean environments.

Main Features

  • Durable stainless steel SUS304/SUS316 internal chamber
  • Mechanical or electromagnetic interlock system
  • Tempered glass window for easy observation
  • Smooth rounded designed corners for effortless cleaning
  • Optional UV lamp for sterilization

Key Advantages

  • Lower investment costs
  • Simple structure, easy maintenance
  • Zero continuous power consumption
  • High operational reliability and long service life

Dynamic Pass Box

Dynamic Pass Boxes are equipped with a built-in HEPA/ULPA filtration system and operate with positive pressure airflow. These pass boxes are used when transferring materials from lower-grade areas to higher-grade cleanrooms. They function like a mini air-cleaning chamber, removing dust and particles before opening into the cleaner zone.

Main Features

  • High-efficiency HEPA H13/H14 or ULPA filters
  • EC fan motor providing stable laminar airflow
  • Digital display for pressure and operating status
  • Electromagnetic interlock for door safety
  • Optional PLC touchscreen control system

Key Advantages

  • Ensures material cleanliness upon transfer
  • Improves GMP compliance for critical grade shifts
  • Maintains pressure and prevents backflow contamination
  • Active particle purging within 15–30 seconds

Static vs. Dynamic Pass Box — Detailed Comparison

Categories Static Pass Box Dynamic Pass Box
Airflow No fan or filter (Passive isolation) HEPA/ULPA filtered laminar airflow
Cleanliness Control Basic contamination control High-level active particle reduction
Best Application ISO 7–8 environments, equal-class rooms ISO 5–7, GMP Grade B/C/A boundary zones
Installation Minimum construction requirements Requires power supply & airflow design
Cost More economical investment Higher investment for critical compliance

How to Select the Right Pass Box for Your Facility

Choosing the correct pass box depends on several factors:

  • 1 Cleanliness grade difference: Use Static pass boxes between equal grades (e.g. Grade D to D); use Dynamic pass boxes when transitioning to higher clean zones (e.g. Grade C to B).
  • 2 Material type & transfer frequency: Size the chamber properly to ensure materials do not obstruct door closure or airflow nozzles.
  • 3 Regulatory requirements: Ensure compliance with cGMP, ISO 14644-4, and FDA validation protocols.
  • 4 Interlock preferences: Choose mechanical interlock for non-powered reliability or electromagnetic interlock for audio/visual indicators and timed sterilization.

Frequently Asked Questions (FAQ)

When is it better to choose a Static Pass Box over a Dynamic Pass Box?

Static Pass Boxes are the most appropriate and cost-effective choice if the transfer of goods is carried out between two rooms with the same cleanliness class (for example from a Class D Corridor to a Class D Primary Packing Room, or between non-sterile laboratory rooms). The mechanical/electrical interlock system is sufficient to isolate the two rooms without the need for a blowout filter.

What is the difference between mechanical interlock and electronic interlock?

Mechanical interlocks work purely with an internal steel lever/wire without requiring electrical power, very durable and long lasting. Electronic interlocks use magnetic sensors and electrical solenoids, allowing the integration of indicator lights (green/red), emergency buttons, buzzers and automatic timers for UV lights.

What are the standard dimensions and can custom orders be made?

The most common standard internal dimensions are 500x500x500 mm, 600x600x600 mm and 800x800x800 mm. Farclean manufactures *custom-built* units to match the size of your project's trays, transfer trolleys, or cleanroom wall panel thickness.

Complete Technical Specifications Table

Chamber Materials Full Stainless Steel SUS304 / SUS316L Hairline Finish (Thickness 1.2–1.5mm)
Interlock Mechanism Mechanical Linkage Interlock / Precision Electromagnetic Interlock with LED Status Indicator
Observation Window Double-layer Flush Tempered Glass (5mm + 5mm with Silica Gel Desiccant)
UV Germicidal Disinfection 253.7nm UV-C Germicidal Lamp with Auto Interlock Timer and Door Safety Cutoff
Interior Geometry Fully Radiused Coved Corners (R >= 10mm) for Zero Contamination Dead-Zones
Sealing Gaskets Continuous Closed-Cell Silicone / EPDM Hermetic Gasket Channel
Standard Internal Dimensions 500 x 500 x 500 mm / 600 x 600 x 600 mm / 800 x 800 x 800 mm (Custom Built Available)
Compliance Certification ISO 14644-1 (Class 1–9), cGMP Grade A-D, FDA 21 CFR, CE Certified

Need Custom Specifications or Turnkey Project?

Consult your needs for static/dynamic SUS304/SUS316L pass boxes, electronic interlocks, UV sterilization or cGMP cleanroom facilities with our expert team in Indonesia.

Konsultasi Cepat WhatsApp