GMP & ISO 14644 Certified
PT. Far Clean Indonesia Cleanroom
Pilih Bahasa / Language:
Panduan Spesifikasi Pintu & Panel Cleanroom Tahan Api – PT Far Clean Indonesia
Fire-Rated EI60 / EI120
Standar Uji Bakar & Integritas Bersertifikasi

Telah diuji sesuai standar EN 1634-1, BS 476 Part 22, dan UL 10C dengan segel intumescent yang mengembang saat panas (>180°C).

Pintu & Jendela Cleanroom ID: fc-fire-rated-door

Panduan Spesifikasi Pintu & Panel Cleanroom Tahan Api

Panduan Spesifikasi Teknik & Rekayasa: Pintu dan Panel Cleanroom Tahan Api

Panduan teknis komprehensif yang mencakup peringkat penahanan api, material insulasi inti, segel kedap udara, dan integrasi interlock darurat untuk fasilitas biofarma dan industri yang diatur ketat. Di fasilitas presisi tinggi seperti farmasi, fabrikasi semikonduktor, produksi baterai litium, dan lab biotek, penghalang cleanroom tahan api harus menyeimbangkan standar keselamatan kebakaran (EI30, EI60, EI120) dengan kontrol kontaminasi GMP yang ketat.

Material Inti Utama & Kemampuan:

Rockwool: EI60 / EI120 (Kelas A1) Glass Magnesium / MGO: 60–120 mnt Aluminum Honeycomb + MGO: 30–60 mnt PIR / PU Core: 30–60 mnt (Kelas B1)

Fitur Desain Sistem Cleanroom Tahan Api:

  • ✓ Antarmuka Rata (Flush) & Kemudahan Pembersihan: Kaca tahan api lapis ganda yang diperkuat (pyro-glass) dipasang rata (flush) di kedua sisi untuk mencegah penumpukan debu.
  • ✓ Penyegelan Ganda Kedap Udara & Intumescent: Segel perimeter mengembang pada suhu >180°C untuk menahan asap sementara segel bawah drop-down menjaga tekanan diferensial ruangan harian.
  • ✓ Interlock Darurat & Koneksi Alarm Kebakaran: Kunci magnetik elektronik terintegrasi langsung dengan sistem alarm kebakaran sentral untuk terbuka secara otomatis dan instan saat kondisi darurat.

* Mendukung kualifikasi kebakaran EN 1634-1 / BS 476, integrasi fire alarm BAS, dan sertifikasi material GMP.

Material Inti & Peringkat Api

1. Material Inti Utama & Peringkat Ketahanan Api

Panduan Spesifikasi Pintu & Panel Cleanroom Tahan Api – PT Far Clean Indonesia

Pada fasilitas presisi tinggi seperti farmasi, fabrikasi semikonduktor, produksi baterai lithium, dan laboratorium bioteknologi, penghalang cleanroom tahan api harus menyeimbangkan standar keselamatan kebakaran (EI30, EI60, EI120) dengan kontrol kontaminasi GMP yang ketat:

Tipe Material Inti Peringkat Ketahanan Api Konduktivitas Termal Fitur Utama & Aplikasi Industri
High-Density Rock Wool 60–120 mnt (EI60 / EI120) ~0,040 W/m·K Tidak mudah terbakar Kelas A1, kekuatan struktural tinggi, standar untuk farmasi & area berbahaya
Glass Magnesium / MGO 60–120 mnt ~0,060 W/m·K Ketahanan benturan luar biasa dan kekuatan lentur; sering dikombinasikan dengan Rockwool
Aluminum Honeycomb + MGO 30–60 mnt — Ringan dengan perlindungan api struktural tambahan; banyak digunakan di mikroelektronik ISO 5–7
PIR / PU (Poliisosianurat) 30–60 mnt (Class B1) ~0,022 W/m·K Performa insulasi termal tinggi, ideal untuk cleanroom dingin dan zona sensitif suhu

2. Fitur Desain Sistem Cleanroom Tahan Api

01

Permukaan Rata (Flush) & Kemudahan Pembersihan

Kaca tahan api lapis ganda yang diperkuat (pyro-glass) dipasang rata (flush) di kedua sisi untuk mencegah penumpukan debu. Segel perimeter intumescent mengembang pada suhu tinggi (>180°C) untuk mencegah penyebaran asap sekaligus mempertahankan tekanan diferensial ruang melalui segel drop-down bawah.

02

Lapisan Permukaan & Ketahanan Korosi

Baja galvanis pra-cat (PPGI) dengan pelapis PVDF/Anti-statik (0,6–0,8 mm) atau Stainless Steel SUS304/SUS316L untuk ruang steril yang sering menjalani dekontaminasi VHP (vaporized hydrogen peroxide).

03

Interlock Darurat & Integrasi Alarm Kebakaran

Sistem interlock magnetik elektronik terhubung langsung ke sistem alarm kebakaran sentral untuk melepaskan kunci magnetik seketika saat listrik padam atau kondisi darurat.

Butuh Pintu dan Panel Cleanroom Tersertifikasi Tahan Api untuk Proyek Anda?

Di Farclean, kami memproduksi panel sandwich tahan api, pintu cleanroom baja, dan sistem pintu kedap udara yang telah diuji terhadap standar api EN 1634-1, BS 476, dan UL 10C.

Sudah menyiapkan gambar teknis atau jadwal proyek? Kirimkan kebutuhan Anda hari ini untuk menerima proposal teknik mendetail dan penawaran harga langsung dari pabrik dalam 1–2 hari kerja.

Tabel Spesifikasi Teknis Lengkap

Model Produk Sistem Pintu & Panel Cleanroom Baja Tahan Api
Peringkat Tahan Api EI30 (30 menit), EI60 (60 menit), EI90 (90 menit), EI120 (120 menit)
Material Inti (Core) Rock Wool Kepadatan Tinggi (120 kg/m³) / Papan Magnesium Oksida (MGO) / Komposit Tidak Mudah Terbakar Kelas A1
Material Plat Daun & Kusen Baja Electro-Galvanis 0,8–1,0 mm dengan Lapisan Bubuk PVDF / Stainless Steel SUS304/SUS316L
Sistem Segel Ganda (Dual Seal) Segel Silikon Kedap Udara Harian + Intumescent Graphite Seal (Mengembang otomatis saat suhu >180°C)
Kaca Observasi Tahan Api Kaca Tahan Api Flush Double-Glazed (Pyro-Stop Glass 60–120 menit) Rata Permukaan
Integrasi Sistem Darurat Sistem Interlock Kunci Magnetik Terhubung Alarm Kebakaran (Pelepas Otomatis Saat Sinyal Kebakaran/Padam Listrik)
Sertifikasi & Kepatuhan EN 1634-1, BS 476 Part 22, UL 10C, ISO 14644-1, GMP Grade A–D

Konsultasi Sistem Pintu & Panel Tahan Api Bersertifikasi

Diskusikan kebutuhan pintu tahan api dan sandwich panel Rockwool/MGO bersertifikasi EN 1634-1 / UL 10C untuk fasilitas industri Anda bersama tim ahli PT. Far Clean Indonesia.

Fire-Rated Cleanroom Doors & Panels Specification Guide – PT Far Clean Indonesia
Fire-Rated EI60 / EI120
Certified Burn & Integrity Testing Standards

Has been tested to EN 1634-1, BS 476 Part 22 and UL 10C standards with a heat-developing intumescent seal (>180°C).

Cleanroom Doors & Windows ID: fc-fire-rated-door
Fire-Rated Cleanroom Doors & Panels Specification Guide

Fire-Rated Cleanroom Doors and Panels: Engineering & Technical Specification Guide

A comprehensive technical guide covering fire containment ratings, core insulation materials, airtight seals, and emergency interlock integration for regulated biopharma and industrial facilities. In high-precision facilities such as pharmaceuticals, semiconductor fabrication, lithium battery production, and biotech labs, fire-rated cleanroom enclosures must balance fire safety standards (EI30, EI60, EI120) with strict GMP contamination control.

Key Core Materials & Capabilities:

Rockwool: EI60 / EI120 (Class A1) Glass Magnesium/MGO: 60–120 mins Aluminum Honeycomb + MGO: 30–60 mins PIR/PU Core: 30–60 mins (Class B1)

Design Features of Fire-Rated Cleanroom Systems:

  • ✓ Flush Interfacing & Cleanability: Toughened double-glazed fire glass (pyro-glass) installed flush on both sides to eliminate dust accumulation.
  • ✓ Dual Airtight & Intumescent Sealing: Perimeter seals expand at >180°C to block smoke while drop-down bottom seals maintain daily differential room pressure.
  • ✓ Emergency Interlock & Fire Alarm Linkage: Kunci magnetik elektronik terintegrasi langsung dengan sistem alarm kebakaran sentral untuk terbuka secara otomatis dan instan saat kondisi darurat.

* Supports EN 1634-1 / BS 476 fire qualification, BAS fire alarm integration and GMP material certification.

Core Material & Fire Rating

1. Key Core Materials & Technical Fire Ratings

Fire-Rated Cleanroom Doors & Panels Specification Guide – PT Far Clean Indonesia

In high-precision facilities like pharmaceuticals, semiconductor fabrication, lithium battery production, and biotech labs, fire-rated cleanroom enclosures must balance fire safety standards (EI30, EI60, EI120) with strict GMP contamination control:

Core Material Type Fire Endurance Rating Thermal Conductivity Key Features & Industry Applications
High-Density Rock Wool 60 – 120 mins (EI60 / EI120) ~0.040 W/m·K Non-combustible Class A1, high structural strength, standard for pharma & hazardous areas
Glass Magnesium / MGO 60 – 120 mins ~0.060 W/m·K Exceptional impact resistance and flexural strength; frequently combined with Rockwool
Aluminum Honeycomb + MGO 30 – 60 mins — Lightweight with added structural fire protection; widely used in ISO 5-7 microelectronics
PIR/PU (Polyisocyanurate) 30 – 60 mins (Class B1) ~0.022 W/m·K High thermal insulation performance, ideal for cold cleanrooms and temperature-critical zones

2. Design Features of Fire-Rated Cleanroom Systems

01

Flush Interfacing & Cleanability

Toughened double-glazed fire glass (pyro-glass) is installed flush on both sides to prevent dust settlement. Intumescent perimeter seals expand at high temperatures (>180°C) to prevent smoke propagation while maintaining daily differential pressure via drop-down bottom seals.

02

Surface Finishes & Corrosion Resistance

Pre-painted galvanized steel (PPGI) with PVDF/Anti-static coatings (0.6mm–0.8mm) or Grade 304/316L Stainless Steel for sterile washrooms subjected to frequent VHP (vaporized hydrogen peroxide) decontamination.

03

Emergency Interlock & Fire Alarm Integration

Electronic magnetic interlock systems connect directly to central fire alarm systems to instantly release magnetic locks during power failures or emergency panic states.

Need Certified Fire-Rated Cleanroom Doors and Panels for Your Project?

At Farclean, we manufacture fire-rated sandwich panels, steel cleanroom doors, and air-tight enclosure systems tested against EN 1634-1, BS 476, and UL 10C fire standards.

Have technical drawings or architectural schedules ready? Send us your requirements today to receive a detailed engineering proposal and factory direct quotation within 1-2 business days.

Complete Technical Specifications Table

Product Model Sistem Pintu & Panel Cleanroom Baja Tahan Api
Fire Resistance Rating EI30 (30 minutes), EI60 (60 minutes), EI90 (90 minutes), EI120 (120 minutes)
Core Material (Core) Rock Wool Kepadatan Tinggi (120 kg/m³) / Papan Magnesium Oxide (MGO) / Komposit Non-combustible Kelas A1
Leaf Plate & Frame Material Electro-Galvanized Steel 0.8mm–1.0mm with PVDF Powder Coating / Stainless Steel 304/316L
Double Seal System (Dual Seal) Daily Airtight Silicone Seal + Intumescent Graphite Seal (Automatically expands when temperature >180°C)
Fireproof Viewing Glass Double-Glazed Flush Fire-Resistant Glass (Pyro-Stop Glass 60–120 minutes) Flat Surface
Emergency Systems Integration Magnetic Lock Interlock System Connected to Fire Alarm (Automatic Release at Fire/Blackout Signal)
Certification & Compliance EN 1634-1, BS 476 Part 22, UL 10C, ISO 14644-1, GMP Class A-D

Certified Fire Resistant Door & Panel System Consultation

Diskusikan kebutuhan pintu cleanroom tahan api dan panel sandwich Rockwool/MGO bersertifikat EN 1634-1 / UL 10C untuk fasilitas industri Anda bersama tim ahli PT. Far Clean Indonesia.

Konsultasi Cepat WhatsApp